Indicators ndi Energy Meter
Kufotokozera Kwamtundu
Mtundu | Kanthu | Njira yowonetsera | Mphamvu | Kutseka single | Kutseka kulumikizana kawiri | Ikani | Mwini | Dimension | Kudula kukula | Chithunzi | |
fufuzani | kukhudzana | fufuzani | |||||||||
Mtundu wa Builtin | GPXN-Q | Dinani batani | - | 96x48x88 | 91x44 pa | 3 | |||||
GPXN-T | Dinani batani | 96 × 48 × 55 | 91x44 pa | 3 | |||||||
Swg. | Chithunzi cha GPXN1-Q | Kuwala | - | - | 96x48x88 | 91x44 pa | 1 | ||||
Chithunzi cha GPXN1-T | Kuwala | - | 96 × 48 × 55 | 91x44 pa | 1 | ||||||
GPXN4-Q | Dinani batani | - | - | 144 × 48 × 104 | 138 × 44 pa | 4 | |||||
Chithunzi cha GPXN4-T | Dinani batani | - | 144 × 48 × 104 | 138 × 44 pa | 4 | ||||||
GPXN5-Q | Dinani batani | - | - | 96x48x88 | 91x44 pa | 2 | |||||
Chithunzi cha GPXN5-T | Dinani batani | - | 96 × 48 × 55 | 91x44 pa | 2 | ||||||
Insulator imodzi yokhala ndi 2 Indicators | GPXN4-Q/M | Dinani batani | - | - | 144 × 48 × 104 | 138 × 44 pa | 4 | ||||
GPXN4-T/M | Dinani batani | - | 144 × 48 × 104 | 138 × 44 pa | 4 | ||||||
GPXN4-T/Z | Dinani batani | 144 × 48 × 104 | 138 × 44 pa | 4 | |||||||
Mtundu Wapadera | GPXN1-Q/CS | Kuwala | - | - | - | 96x48x88 | 91x44 pa | ||||
GPXNP1-Q/W | Kuwala | - | - | - | 96x48x88 | 91x44 pa | 1 | ||||
GPXN-Q/LCS | Kuwala | - | - | 96x48x88 | 91x44 pa | 3 |
Voltage Indicator Yogwiritsidwa Ntchito mu Ring Main Unit
Chizindikiro chamagetsi chimagwiritsidwa ntchito limodzi ndi insulator kuwonetsa momwe magetsi amayendera.
Chojambulira chamagetsi chopitilira GPXN9-C chimagwiritsidwa ntchito ndi chizindikiro kuwonetsa dziko lamagetsi.Mtunda wa dzenje la terminal yowunika mphamvu ndi 14mm kapena 19mm.
Phase comparator GPXN-C imagwiritsidwa ntchito ndi chizindikiro kuwonetsa mawonekedwe amagetsi amagetsi apamwamba kwambiri ndikuwunika magawo a zida zamagetsi.
Kuwunika kwamphamvu: kuyerekeza gawo kuyika mu nthaka kapena ma terminals ena a zida zamphamvu kwambiri.
Phase-cheke: gawo comparator ikani mu gawo lomwelo mphamvu-cheke terminal ya zida ziwiri zamphamvu kwambiri, ngati kuwala kwa LED kuli kowala, zikuwonetsa kuti gawo loyesa lili ndi magetsi.
Chizindikiro cha Udindo
Chizindikiro cha malo amatha kutengera momwe amagwirira ntchito komanso momwe zidasinthira ngati switch ndi chophwanyira magetsi mumagetsi.Amagwiritsidwa ntchito kwambiri pamitundu yonse yamitundu yotsatsira ya chipinda chowongolera chapakati ndi gulu la switchgear mumagetsi, malo opangira magetsi ndi ma transfoma.Zizindikiro zotsatizanazi zimakhala ndi kudalirika kwakukulu, mphamvu zambiri zogwirira ntchito komanso moyo wautali.DC ndi AC zilipo kuti zigwiritsidwe ntchito.
Magawo aukadaulo
Adavotera mphamvu | DC/AC 98V~242V |
Kuwala kowala | >40 cd/㎡ |
Ma frequency amphamvu amapirira voteji | 2 kV / 1 mphindi |
Insulation resistance | ≥100MΩ |
Kutaya mphamvu | ≤1W |
Kutentha kwa ntchito | -15 ℃ mpaka +50 ℃ |
Utali wamoyo | >10 zaka |
Ntchito yowonetsera | Kugwira ntchito kumawonetsedwa ndi mtundu wofiira/wobiriwira ndi zithunzi (Monga njira yamakasitomala) |
Muyeso wa autilaini: | 37.5×37.5×62(mm) |
Kudula kukula: | Φ25(mm) |
Chitsanzo | Kufotokozera |
GPWZ25-K/2 | Position Indicator-Circuit-Breaker |
GPWZ25-E/1 | Position Indicator-Earthing Switch |
GPWZ25-B/2 | Position Indicator-Hand Truck |
GPWZ25-B/1 | Position Indicator-Disconnector |
GPWZ25-K/1 | Chizindikiro cha malo- Kusintha kwa malo atatu |
Position Ikusonyeza Screen GPAS-72
The GPAS-72 siriyo udindo kusonyeza chophimba utenga LED monga gwero kuwala, ndi otsika mphamvu mowa, kudalirika mkulu, moyo wautali utumiki, etc. Ndipo angagwiritsidwe ntchito mitundu yonse ya switchgears monga udindo kusonyeza chophimba ndi njira zosiyanasiyana zojambula dongosolo.Ndi ntchito zambiri zowonetsera gawo-voltage, interlock, kutentha & humidity control, chisonyezero cha malo a ngolo yamanja, chisonyezero cha mawonekedwe a circuit breaker, chisonyezero cha kusintha kwa dziko, chisonyezero cha mphamvu zosungidwa.Ndi chisankho chabwino kusintha chizindikiro cha chikhalidwe cha single switch state.
Magawo aukadaulo
Adavotera mphamvu | AC/DC 110V/220V |
Mphamvu pafupipafupi kupirira | 2 kV/mphindi |
Malo ogwirira ntchito | -25 ℃ mpaka 55 ℃, ≤90% RH |
Kuwala kowala kwa analogi | >40cd/m2 |
Moyo wogwira ntchito | 10 zaka |
Chitetezo mlingo | IP42 |
Dimension | 199x146x63mm |
Kudula kukula | 177x121mm |
Technical ParametersGpj-3100 Series Short Circuit And Earth Fault Indicator
Mndandanda wa GPJ-3100 wafupikitsa ndi chizindikiro cha zolakwika zapadziko lapansi adapangidwa kuti ayese ndikuwonetsa kupotoza kwafupipafupi ndi dziko lapansi munthawi yeniyeni.Imagwiritsidwa ntchito poyang'anira mayendedwe mu RMU, mzere wapamwamba, chingwe chogawa magetsi, chosinthira bokosi ndi malo ena ofanana.Malinga ndi chizindikiro cha alamu chomwe chikuwonetsedwa ndi chizindikiro, ogwira ntchito amatha kudziwa ndikudula malo olakwika mwachangu pakachitika vuto laling'ono kapena vuto lapadziko lapansi, kotero kuti dongosololi litha kuyambiranso kupereka mphamvu m'malo omwe alibe vuto mwachangu kuti asunge nthawi ndikuwongolera magwiridwe antchito.
Deta yaukadaulo
1. Kuzungulira kwakanthawi kowopsa: 100A mpaka 1000A kuchedwa kwanthawi 40ms
2. Zowopsa zapano: 20A, 30A, 40A, 50A, 60A± 10% kuchedwa kwa nthawi 40ms
3. Kutentha osiyanasiyana: -25 kuti +70 ℃
4 Chinyezi osiyanasiyana: ≦95%
5. Kutalika kwa tsogolo: 4m
6. Pangani kuwala kwa fiber kutalika kwa 3.5m
7. Mphamvu yamagetsi: lithiamu batire 3.6V/2.45Ah
8. Kukhazikitsanso nthawi: 7s, 2hrs,4hrs,8hrs
9. Kutulutsa kotulutsa: 120 V AC 1A, 30V DC 2A
10.Main controller dimension: 95x50x80mm
11.Kudula dzenje kukula : 91x44 mm
12.Kalasi yotetezedwa : Wolamulira Wamkulu : IP40, Sensor: IP65