12/24/40.5kV Shutter Assembly And Interlocking
Shutter Assembly 5GP.320.010 Kukhazikitsa Chithunzi
(800mm m'lifupi-woyika switchgear)
Shutter Assembly 5GP.320.010 Mndandanda Wokonzekera
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
1 | Bokosi lothandizira lamanja | 8GP.123.011 | 1 |
2 | Cholumikizira cholumikizira kumanja | 5GP.235.011 | 1 |
3 | Kuwonetsa tag | 8GP.866.014 | 1 |
4 | Kulumikizana kumanzere | 5GP.235.010 | 1 |
5 | Chipinda chothandizira chakumanzere | 8GP.123.010 | 1 |
6 | kugwirizana kuwotcherera | 5GP.174.016.1(Kwa VD4) | 2 |
5GP.174.016.2(Ya GPVN) | |||
5GP.174.016.3(Kwa VB2) | |||
7 | Chipata chotsekera pansi | 8GP.320.010 | 1 |
8 | Block yadzaza 8 | DK-8 | 8 |
9 | mbale ya bracket | 8GP.123.013 | 3 |
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
10 | kugwirizana kuwotcherera | 5GP.174.017.1(Kwa VD4, 40kA) | 2 |
5GP.174.017.2(Kwa VD4, 31.5kA) | |||
5GP.174.017.3(Kwa GPVN) | |||
5GP.174.017.4(Kwa VB2) | |||
11 | Kuwonetsa tag | 8GP.866.012 | 1 |
12 | Kuwonetsa tag | 8GP.866.013 | 2 |
13 | mbale ya bracket | 8GP.123.012 | 3 |
14 | Chotsekera chapamwamba | 8GP.320.011 | 1 |
15 | Ndodo yotsogolera | 8GP.234.011(Kwa VD4, GPVN) | 2 |
8GP.234.011.1(Kwa VB2) | |||
16 | Spopper sleeve | 8GP.210.011 | 2 |
Mndandanda wina wamakonzedwe a shutter
Kodi | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Cabinet wide | 650 mm | 700 mm | 840 mm | 900 mm | 1000 mm |
Chipata Chapamwamba | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Chipata chapansi | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Shutter Assembly 5GP.320.011
(1000mm m'lifupi-woyika switchgear)
Shutter Mechanism Chipangizo 5GP.320.011 Mndandanda Wokonzekera
(1000mm m'lifupi-woyika switchgear)
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
1 | Bokosi lothandizira lamanja | 8GP.123.276 | 1 |
2 | Cholumikizira cholumikizira kumanja | 5GP.235.012 | 1 |
3 | Kuwonetsa tag | 8GP.866.014 | 1 |
4 | Cholumikizira chakumanzere | 5GP.235.013 | 1 |
5 | Chipinda chothandizira chakumanzere | 8GP.123.275 | 1 |
6 | Kugwirizana weld msonkhano | 5GP.174.281 | 2 |
7 | Chotsekera pansi | 8GP.320.273 | 1 |
8 | Block yadzaza 10 | DK-10 | 8 |
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
9 | mbale ya bracket | 8GP.123.278 | 3 |
10 | Cholumikizira chowotcherera cholumikizira | 5GP.174.282 | 2 |
11 | Kuwonetsa tag | 8GP.866.012 | 1 |
12 | Kuwonetsa tag | 8GP.866.013 | 2 |
13 | mbale ya bracket | 8GP.123.277 | 3 |
14 | Chotsekera chapamwamba | 8GP.320.274 | 1 |
15 | Ndodo yotsogolera | 8GP.234.272 | 2 |
16 | Spopper sleeve | 8GP.210.011 | 2 |
Mndandanda wina wamakonzedwe a shutter
Kodi | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Cabinet wide | 800 mm | 1000mm (Kuteteza) | 1100 mm | 1200 mm |
Chipata Chapamwamba | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Chipata chapansi | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Zindikirani: 5GP.320.275 ndi yotsekereza shutter ndi mbale ya SMC pakati ndipo onse amathera ndi mbale yachitsulo, chotsekera china ngati pakufunika chipata chotchinga chonde tchulani.
Earthing lophimba ntchito limagwirira interlock chipangizo (Pa kugwirizana mkono pagalimoto ntchito) 5GP.363.010.1 msonkhano chithunzi
Malangizo a Interlock Chipangizo
Chipangizo cholumikizira chimawonjezedwa cholumikizira chakumbuyo ndi chitseko chakumbuyo chomwe chidapangidwa pamaziko a chipangizo choyambirira cha 5GP.363.010 cholumikizira cholumikizira.Ndiko kuti, chotchinga chapansi chikatsekedwa ndikutsegula chitseko chakumbuyo (mbale yosindikizira), cholumikizira choyambirira chimatha kugwiritsabe ntchito chosinthira, koma cholumikizira ichi sichinathe.Muyenera kutseka chitseko chakumbuyo (mbale yosindikizira) kuti mugwiritse ntchito switching.
Mfundo zogwirira ntchito za chipangizo cholumikizira zimasinthidwa cholumikizira cha No.Chitseko chakumbuyo (chisindikizo chosindikizira) chikatsegulidwa, mkono wa loko umalowa mu dzenje lalikulu la kabati (kukula kovomerezeka 35X35), switching earthing singagwire ntchito.
Chida cholumikizira cholumikizira cha Earthing switch (Pa ntchito yolumikizira mkono pagalimoto)
5GP.363.010.1 mndandanda wa dongosolo.
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
1 | Kubereka | 8GP.263.011 | 1 |
2 | Gawo | 8GP.192.010 | 1 |
3 | Gawo | 8GP.192.011 | 1 |
4 | Mtsinje wa axis | 8GP.210.014.1 | 2 |
5 | Gawo | 8GP.151.041 | 1 |
6 | Mtsinje wa axis | 8GP.211.061 | 1 |
7 | Gawo | 8GP.151.039 | 1 |
8 | Mtsinje wa axis | 8GP.211.062 | 1 |
9 | Bolt M5 × 12 | GB70-85 | 1 |
10 | Gawo | 8GP.151.042 | 1 |
11 | Gawo | 8GP.151.043 | 1 |
12 | Ntchito ndodo | 8GP.200.013.1 (Yaitali 1432 ya kuya kwa nduna 1500 kuya) | 1 |
8GP.200.013.2 (Yaitali 1590 ya kuya kwa nduna 1660) | 1 | ||
13 | Chothandizira mbale | 8GP.161.058 | 1 |
8GP.161.058.1(Posankha) | 1 |
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
14 | Chophimba | 8GP.017.011.1 | 1 |
15 | Bulaketi | 5GP.043.022 | 1 |
16 | Chothandizira mbale | 8GP.161.059 | 1 |
17 | Slider | 8GP.143.010 | 2 |
18 | Mtsinje wa axis | 8GP.211.058 | 1 |
19 | Spopper sleeve | 8GP.211.057 | 3 |
20 | Thandizo maziko | 8GP.043.019 | 1 |
21 | Tsekani kusonyeza | 8GP.866.010 | 1 |
22 | Mgwirizano wa ndodo | 5GP.233.030.1 | 1 |
5GP.233.030.3(Kusankha) | 1 | ||
23 | Tsegulani kusonyeza | 8GP.866.011 | 1 |
24 | Locking sleeve | 8GP.211.201 | 1 |
25 | Mbale ya pulagi ya mano | 8GP.151.044 | 1 |
26 | Mtsinje wa axis | 8GP.211.060 | 2 |
27 | Tagi | 8GP.860.010 | 1 |
28 | Pressure spring | 8GP.282.201 | 1 |
29 | Kutsekera kwa manja Bolt | 8GP.920.002 | 1 |
Zindikirani:
1. No. 1-12 onani tsamba lapitalo.
2. No. 22 Connection ndodo msonkhano, kugwirizana mkono ali awiri kukula: Cabinet pakati mtunda 60mm ofanana.Ngati mukufunikira mtunda wapakati wa 80mm chonde onani tsamba 17 malangizo olumikizirana ndi mkono, ndipo tchulani poyitanitsa.
Earthing lophimba ntchito limagwirira interlock chipangizo (Pa ntchito bevel zida pagalimoto) 5GP.577.1001
Earthing lophimba ntchito limagwirira interlock chipangizo (Pa ntchito bevel gear pagalimoto) 5GP.577.1001 dongosolo mndandanda
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
1 | Kubereka | 8GP.263.011 | 1 |
2 | Choyimitsa mbale | 8GP.151.084 | 2 |
3 | Mtsinje wa axis | 8GP.210.014.1 | 2 |
4 | Gawo | 8GP.151.041 | 1 |
5 | Mtsinje wa axis | 8GP.210.014.2 | 1 |
6 | Bolt M5X12 | GB70-85 | 1 |
7 | Gawo | 8GP.151.042 | 1 |
8 | Gawo | 8GP.151.043 | 1 |
9 | Mtsinje wa axis | 8GP.210.014.3 | 1 |
Ayi. | Dzina | Kujambula No. | Qty.(pc/set) |
10 | Spopper sleeve | 8GP.210.322 | 1 |
11 | Ntchito ndodo | 8GP.174.214 | 1 |
12 | Chophimba | 8GP.017.011.2 | 1 |
13 | Thandizo maziko | 5GP.043.022 | 1 |
14 | Slider | 8GP.143.010 | 2 |
15 | Chothandizira mbale | 8GP.161.059 | 1 |
16 | Chothandizira mbale | 8GP.161.058 | 1 |
17 | Mbale ya pulagi ya mano | 8GP.151.044 | 1 |
18 | Tagi | 8GP.860.010 | 1 |
Chidziwitso: 1. Makinawa amafunika kutsekedwa ndi chitseko chotsika, chonde tchulani poyitanitsa.