12 17.5 24kV M'nyumba Vacuum Circuit Breakers, GPVN-E Series
Ambient Condition
Kutentha kozungulira: -25 ℃ ~ + 45 ℃, pafupifupi tsiku lililonse: ≤35 ℃
Kutalika: 1000m (Standard);akhoza mpaka 4500m kuyitanitsa wapadera;
Chinyezi chachibale: pafupifupi tsiku lililonse ≤95%, pafupifupi pamwezi ≤90%;
Kuchuluka kwa chivomerezi ≤8 digiri;
Zomwe zikuyenera kuchitika ziyenera kukhala zopanda zoyaka, zophulika, zowononga komanso kugwedezeka kwakukulu.
Chitsanzo
![10](http://www.gpswitchgear.com/uploads/107.jpg)
GPVN -12Kv/17.5kV M'nyumba AC High Voltage Vacuum Circuit Breaker
Mfundo Zaukadaulo
Ayi. | Kanthu | Chigawo | Deta | ||||||
1 | Adavotera mphamvu | kV | 7.2~12(15/17.5) | ||||||
2 | Adavoteledwa pafupipafupi | Hz | 50/60 | ||||||
3 | Zovoteledwa panopa | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | Idavoteredwa ndi kuphulika kwafupipafupi | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Idavoteredwa kuti ipange nthawi yayitali | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Idavoteredwa kwakanthawi kochepa | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Chiwongola dzanja chovomerezeka | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Chiyembekezo chokokera kunja chakuphulika | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Adavoteledwa ndi vuto lakunja kwa gawo lomwe likuphulika | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Idavotera nthawi yakusweka kwanthawi yayitali | Nthawi | 50 | 30 | 30 | 12 | |||
11 | Adavoteledwa kachitidwe | O-0.3s-CO-180s-CO | O-180s-CO-180s-CO | ||||||
12 | Adavotera kusweka kwa banki ya single capacitor | A | 630 | ||||||
13 | Adavotera kusweka kwa banki yakumbuyo kupita ku banki ya capacitor | A | 400 | ||||||
14 | 1 min.Ma frequency amphamvu amapirira voteji | kV | Gawo mpaka gawo / padziko lapansi: 42, kudutsa otseguka: 48 | ||||||
15 | Mphamvu ya mphezi imapirira voteji | kV | Gawo mpaka gawo / padziko lapansi: 75, kudutsa otseguka: 85 | ||||||
16 | Moyo wamakina | Nthawi | 20000 | ||||||
17 | Nthawi yotseka | ms | ≤75 | ||||||
18 | Nthawi yotsegulira | ms | ≤60 | ||||||
19 | Nthawi yosungirako mphamvu pansi pa voliyumu yovotera | s | ≤10 |
Chithunzi cha GPVN-12E
![20](http://www.gpswitchgear.com/uploads/20.jpg)
![30](http://www.gpswitchgear.com/uploads/30.jpg)
GPVN-24 □ M'nyumba AC High Voltage Vacuum Circuit Breaker
Kufotokozera zaukadaulo
Ayi. | Kanthu | Chigawo | Deta | |||
1 | Adavotera mphamvu | kV | 24 | |||
2 | Adavoteledwa pafupipafupi | Hz | 50/60 | |||
3 | Zovoteledwa panopa | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Idavoteredwa ndi kuphulika kwafupipafupi | kA | 20 | 25 | 31.5 | 31.5 |
5 | Idavoteredwa kuti ipange nthawi yayitali | kA | 50 | 63 | 80 | 80 |
6 | Kupirira kwanthawi yayitali (4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Chiwongola dzanja chovomerezeka | kA | 50 | 63 | 80 | 80 |
8 | Adavoteledwa ngati akudutsa | kA |
|
| 12.6 | 12.6 |
9 | Zovoteledwa ndi vuto lakunja kwa gawo lapansi | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Idavoteredwa nthawi yakusweka kwamagetsi afupipafupi | Nthawi | 50 | |||
11 | Adavoteledwa kachitidwe |
| O-0.3s-CO-180s-CO | |||
12 | Adavotera kusweka kwa banki ya single capacitor | A | 630 | |||
13 | Adavotera kusweka kwa banki yakumbuyo-kumbuyo capacitor | A | 400 | |||
14 | 1 min.Ma frequency amphamvu amapirira voteji | kV | 50 | |||
15 | Mphamvu ya mphezi imapirira voteji | kV | 125 | |||
16 | Moyo wamakina | Nthawi | 20000 | |||
17 | Nthawi yotseka | ms | 75 | |||
18 | Nthawi yotsegulira | ms | 60 | |||
19 | Nthawi yosungira pansi pamagetsi ovotera | s | 10 |
Kukula kwa GPVN-24E/(630~1250A) Ophwanya
![40](http://www.gpswitchgear.com/uploads/40.jpg)
Kukula kwa GPVN-24E/(1600 ~ 3150A) Ophwanya
![50](http://www.gpswitchgear.com/uploads/50.jpg)