GPR-24(12)kV Series Ring Main Unit Switchgear
Chidule
GPR-24 Ring Main Unit ndi chowonjezera, SF6 insulated switchgear, yokhala ndi voteji ya 12&24 kV.Zigawo zake zonse zamoyo za HV zili mu thanki ya gasi yosalowa mpweya, yomwe imapangidwa kuchokera ku chitsulo chosapanga dzimbiri cha 3mm.Msonkhano wonse wosinthira ndi SF6 wotsekeredwa, komanso wopanda chikoka chilichonse chakunja, kuwonetsetsa kudalirika kwakukulu kwautumiki ndi kukonza kwaulere.Pogwiritsa ntchito plug-in mtundu wa busbar extension, GPR-24 Ring Main Unit ikhoza kukhala yophatikizana mwaulere komanso modularization yonse.Kuwonjezedwa kwa busbar kwadutsa mayeso amtundu wa mphamvu ndi kukhazikika kwamafuta, ndipo kumakhala kotetezedwa bwino komanso kotetezedwa, kuwonetsa kudalirika komanso chitetezo.GPR-24 mndandanda Ring Main unit ndi yoyenera kwa ma netiweki onse a MV mpaka 24 kV, malo onse ophatikizika magetsi, malo ogawa magetsi m'mafakitale onse ofunikira, monga mafakitale amafuta amafuta, mafakitale azitsulo ndi migodi, ndi malo onse osinthira magetsi ndi mphamvu yamphepo. dongosolo.
Mawonekedwe
1. Njira zamakono zopangira thanki yamafuta
Dongosolo loyang'aniridwa ndi digito la laser kudula ndi kukhomerera ndi njira yowotcherera yamitundu itatu ndi ma axis asanu yotumizidwa kuchokera ku Germany ndikuwonetsetsa kulimba kwa gasi komanso kufanana kwa matanki onse a gasi.
Dongosolo lodziwikiratu komanso lophatikizika kwambiri la helium lodziwikiratu, lopangidwa ndi SEILER Vakuumtechnik GmbH, pozindikira kutayikira kwa Helium ndi ma spectrograph ambiri, kumabweretsa kuchuluka kwa gasi pachaka kutsika pansi pa 0.02%, kuwonetsetsa kuti thanki yamafuta imakhala yopitilira zaka 30.
MwaukadauloZida ndondomeko njira zigawo.
Ziwalo zonse za epoxy resin insulated, kuphatikiza mizati yotsekeredwa, amapangidwa ndi makina odziyimira pawokha komanso oyendetsedwa ndi digito epoxy resin vacuum mixing/pressure gelatinizing system from Hedrich (Germany) .
Cholumikizira mabasi, cholumikizira chingwe, pulagi yomaliza ndi zida zina zotchingira mphira za silikoni zimapangidwa ndi makina osakanikirana ndi makina osakanikirana a silicone / kukakamiza gelatinizing kuchokera ku VOGEL (Switzerland).
2. Njira zabwino kwambiri zopangira zinthu
Ndi mawonekedwe ang'onoang'ono komanso ophatikizika, mayunitsi oyambira K, T, V, B ndi C ali ndi mawonekedwe ofanana: 350*800*1380 mm (m'lifupi*kuya* kutalika) .
Mayankho athunthu:
Mtundu umodzi: unit break switch switch, switch-fuse unit, vacuum circuit breaker unit, busbar subsection unit, chingwe unit, metering unit, etc.
Mtundu wa block ukhoza kupangidwa ndi magawo awiri, atatu, anayi, asanu kapena asanu ndi limodzi.
Mayunitsi amodzi ndi mtundu wa block amatha kulumikizidwa ndi zolumikizira mabasi mosinthika.
3. Kusinthasintha kwamphamvu kwa chilengedwe
The chachikulu conductive dongosolo ndi losindikizidwa kwathunthu mu thanki gasi SF6 ndipo si kutengera chilengedwe kunja, popanda zotsatira za mame, fumbi, mchere chifunga, etc. .
12kV Technical Data
Kufotokozera | Chigawo | Mtengo wa LBS | Switch-fuse unit | Mtengo wapatali wa magawo VCB | Gawo lagawo la mabasi | |
Adavotera mphamvu | kV | 12 | 12 | 12 | 12 | |
Ma frequency amphamvu opirira (1min) | Gawo mpaka gawo / dziko lapansi | kV | 42 | 42 | 42 | 42 |
Kudutsa mtunda wodzipatula | kV | 48 | 48 | 48 | 48 | |
Mphamvu zimapirira voteji | Gawo mpaka gawo / dziko lapansi | kV | 75, (95)* | 75, (95)* | 75, (95)* | 75, (95)* |
Kudutsa mtunda wodzipatula | kV | 85, (110)* | 85, (110)* | 85, (110)* | 85, (110)* | |
Adavoteledwa pafupipafupi | Hz | 50,60 | 50,60 | 50,60 | 50,60 | |
Zovoteledwa panopa | A | 630 | ① | 630 | 630 | |
Idavoteredwa ndi break circuit breaking current | kA |
| ② | 20, (25)* |
| |
Idavoteredwa kwakanthawi kochepa kupirira pakali pano | kA/s | 20/3, (20/4, 25/1)* |
| 20/3, (20/4, 25/3)* | 20/3, (20/4, 25/1)* | |
Chiwongola dzanja chovomerezeka | kA | 50, (63)* |
| 50, (63)* | 50, (63)* | |
Zovoteledwa pakupanga ma circuit short | kA | 50, (63)* | ② | 50, (63)* | 50, (63)* | |
Adavotera kusamutsa panopa | A |
| 1800 |
|
| |
Adavoteledwa ndi katundu wokhazikika | A | 630 |
|
| 630 | |
Adavoteledwa ndi kuphulika kwa loop yotsekedwa | A | 630 |
|
| 630 | |
5% idavotera katundu wokhazikika | A | 31.5 |
|
| 31.5 | |
Adavoteledwa kachitidwe |
|
|
| O-0.3s-CO-180s-CO |
| |
Umakaniko moyo | Ops. | 5000 | 5000 | 10000 | 5000 | |
Moyo wamagetsi |
| E3 |
| E2 | E3 | |
Kukhuthala kwachitsulo chosapanga dzimbiri | mm | 3.0 | ||||
Adavotera SF6kupanikizika | kPa | 30 (pa 20 ℃, 101.3kPa) | ||||
Pachaka kutayikira mlingo | <0.02% | |||||
Mayeso ochizira madzi | 12kV maola 24 (pa 30 kPa pansi pa madzi) | |||||
Mayeso amkati arc | 20kA1 ndi | |||||
Digiri ya chitetezo | Tanki yamafuta | IP67 | ||||
Fuse holder | IP67 | |||||
GPR enclosure |
| IP 4X |
24kV Technical Data
Kufotokozera | Chigawo | Mtengo wa LBS | Switch-fuse unit | Mtengo wapatali wa magawo VCB | Gawo lagawo la mabasi | |
Adavotera mphamvu | kV | 24 | 24 | 24 | 24 | |
Ma frequency amphamvu opirira (1min) | Gawo mpaka gawo / dziko lapansi | kV | 50, (65)* | 50, (65)* | 50, (65)* | 50, (65)* |
Kudutsa mtunda wodzipatula | kV | 64, (79)* | 64, (79)* | 64, (79)* | 64, (79)* | |
Mphamvu zimapirira voteji | Gawo mpaka gawo / dziko lapansi | kV | 95, (125)* | 95, (125)* | 95, (125)* | 95, (125)* |
Kudutsa mtunda wodzipatula | kV | 110, (145)* | 110, (145)* | 110, (145)* | 110, (145)* | |
Adavoteledwa pafupipafupi | Hz | 50, 60 | 50, 60 | 50, 60 | 50, 60 | |
Zovoteledwa panopa | A | 630 | ① | 630 | 630 | |
Idavoteredwa ndi break circuit breaking current | kA |
| ② | 20 |
| |
Idavoteredwa kwakanthawi kochepa kupirira pakali pano | kA/s | 20/3, (20/4)* |
| 20/3, (20/4)* | 20/3, (20/4)* | |
Chiwongola dzanja chovomerezeka | kA | 50 |
| 50 | 50 | |
Zovoteledwa pakupanga ma circuit short | kA | 50 | ② | 50 | 50 | |
Adavotera kusamutsa panopa | A |
| 1400 |
|
| |
Adavoteledwa ndi katundu wokhazikika | A | 630 |
|
| 630 | |
Adavoteledwa ndi kuphulika kwa loop yotsekedwa | A | 630 |
|
| 630 | |
5% idavotera katundu wokhazikika | A | 31.5 |
|
| 31.5 | |
Adavoteledwa kachitidwe |
|
|
| O-0.3s-CO-180s-CO |
| |
Umakaniko moyo | Ops. | 5000 | 5000 | 10000 | 5000 | |
Moyo wamagetsi |
| E3 |
| E2 | E3 | |
Kukhuthala kwachitsulo chosapanga dzimbiri | mm | 3.0 | ||||
Kuthamanga kwa SF6 | kPa | 30 (pa 20 ℃, 101.3kPa) | ||||
Pachaka kutayikira mlingo | <0.02% | |||||
Mayeso ochizira madzi | 24kV maola 24 (pa 30 kPa pansi pa madzi) | |||||
Mayeso amkati arc | 20kA1 ndi | |||||
Digiri ya chitetezo | Tanki yamafuta | IP67 | ||||
Fuse holder | IP67 | |||||
GPR enclosure | IP 4X |
Ndemanga:
① Kuvoteledwa kwa ma switch-fuse unit kumadalira mtundu wa fuse: ≤100A
② Kuvotera kwafupipafupi kusweka / kupanga kwanthawi ya switch-fuse unit kutengera mtundu wa fusesi
* Makhalidwe omwe ali m'mabulaketi ndi ofunikira mwapadera, chonde lemberani wopanga kapena wogulitsa kuti mumve zambiri
GPR24 Series mwachidule
1. Mtundu wa thanki imodzi
Zindikirani:
1. Makhalidwe m'mabulaketi olembedwa ndi"*" ndi zinthu zomwe zili pa 24kV, ma frequency amphamvu amapirira voteji ya 65/79kV;
2. Ngati pali zigawo zambiri zachiwiri pakukonzekera, chipinda chowonjezera cha iwo chikhoza kuikidwa pamwamba pa gululo, kutalika kwake ndi 400mm.
2. GPR24 Block Type-1 ya 12kV & 24kV(mphamvu pafupipafupi kupirira voteji: 50/64kV)
Ndemanga:
Ngati pali zigawo zambiri zachiwiri mu kasinthidwe, chipinda chowonjezera cha iwo chikhoza kuikidwa pamwamba pa GPR, kutalika kwake ndi 400mm.