ACB ndi MCCB
Chidule
GPU1/2/3 Series smart universal air circuit breaker lapangidwa zopangidwa ndi ife, oveteredwa voteji ya AC 50/60Hz, 480V(690V), oveteredwa panopa 200A~6300A, makamaka ntchito yogawa mphamvu ndi mabwalo chitetezo kugawa mphamvu. maukonde, kupewa magetsi ndi kuwonongeka kwa zida zamagetsi ku vuto la mochulukira, yochepa dera, dziko vuto, etc.. Iwo ali mkulu mwatsatanetsatane kusankha chitetezo ndi kusintha kudalirika kwa magetsi.Breaker ilinso ndi ntchito yodzipatula, imagwirizana ndi muyezo wa GB 14048.2, IEC 60947-2
Mawonekedwe
1. Kapangidwe kakang'ono
2. Palibe flashover mtunda Chitetezo chachikulu
3. Kuchuluka kwa On-Off
4. Smart mtundu pa-panopa chitetezo ulendo, ndi mawonekedwe kulankhulana, Ikhoza kulamulidwa ndi gulu kompyuta, anazindikira ntchito kutali.
5. Kuwonetsa ntchito ya ammeter, voltmeter
6. Kutsika ndi kutsika komwe kukubwera sikungakhudze magwiridwe antchito
Chitsanzo
GPU 3 | Universal air circuit breaker |
1600 | Shield chimango panopa |
4 | 3 3-gawo osati chizindikiro 4 4-gawo |
3M mtundu smart controller | Smart controller Mtundu wa 2M: Chiwonetsero cha chubu cha digito, kusintha mabatani, gawo la 3 lokhala ndi ntchito yoteteza zolakwika Mtundu wa 3M: Chiwonetsero cha LCD, kusintha kwa batani, gawo la 3 lokhala ndi ntchito yoteteza zolakwika Mtundu wa 3H: Chiwonetsero cha LCD, kusintha mabatani ndi kulumikizana, gawo la 3 ndi ntchito yoteteza chitetezo chamthupi. |
Njira yokwera | Mtundu wojambula Mtundu wokhazikika |
Connect njira | Wiring yopingasa yowongoka mawaya Plate-kumbuyo mawaya kutsogolo |
Chalk kusankha | Under-voltage tripper Kulumikizana kwamakina: 2 seti kapena 3 seti yosweka mu lever yoyima yolumikizidwa 2 seti yosweka yopingasa kapena yoyima yolumikizidwa ndi chingwe chachitsulo "Open" malo loko (kutseka kwa kiyi) Draw-out 3 position switch Cholumikizira chakunja cholumikizira cha N gawo |
Ku =630 | Zovoteledwa pano (A) |
Zindikirani:
1. Smart controller ndi mtundu wa M;Kusintha kothandizira: Magulu a 4 olumikizana nawo, Njira yolumikizira ili yopingasa.
2. Smart controller, shunt release device, close electromagnetic, motor drive mechanism ndi under-voltage tripper zidzatchulidwa mtengo wamagetsi poyitanitsa.
Technical Selection Table
Mtundu | Adavotera voteji ya Ue (V) | Adavotera insulating voteji Ui (V) | Mphamvu yamphamvu yolimbana ndi voliyumu ya Uimp (V) | Chishango chimango Inm (A) panopa | Zovoteledwa panopa Ine (A) | Gawo nambala |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU 1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU 1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU 1-6300 | 6300 | 4000, 5000, 6300 |
Short-circuit kuswa mphamvu | Idavoteredwa kwakanthawi kochepa kupirira Icw (kA)/1s | Kuchita kwa ntchito | |||||
Icu (kA) yoyezedwa kwambiri | Kuvotera kuthamanga kwafupipafupi kuphwanya mphamvu Ics (kA) | Moyo wamakina (nthawi) | Moyo wamagetsi (nthawi) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000 (5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Molded Case Circuit Breaker
GPM11Z Smart Molded Case Circuit Breaker
Chidule cha GPM11/GPM11Z
GPM11 mndandanda kuumbidwa mlandu dera wosweka ndi oyenera AC 50/60Hz oveteredwa ntchito voteji 400V/630V, oveteredwa panopa mpaka 800A ya magetsi kugawa maukonde kwa kugawa mabwalo mphamvu ndi chitetezo, magetsi ndi zipangizo zamagetsi motsutsana mochulukira, pansi-voltage ndi kuopsa kwafupipafupi, kumapangitsa kudalirika kwa magetsi pansi pazikhalidwe zogwiritsira ntchito zomwe sizimayambira kawirikawiri monga kutembenuka kwa mzere ndi injini.Komanso ndi kudzipatula ntchito komanso.Imakumana ndi muyezo wa GB/T 14048.2 ndi IEC 60947-2.
Chitsanzo
Chithunzi cha GPM11GPM11Z | Mlandu Wopangidwa Ndi Circuit BreakerSmart Molded Case Circuit Breaker |
100 | Shield chimango panopa |
H | Kuthamanga kwafupipafupi:N: Mtundu wamba S: Mtundu wokhazikikaH: Mtundu wosweka kwambiri |
P | Njira yogwiritsira ntchito: Opaleshoni yamoto: Chogwirira cha Protate chimagwira ntchito: ZDirect ntchito (palibe code) |
2 | Chitetezo chachitetezo Kusankha:chitetezo chogawa: palibe codeMotor Chitetezo: 2 |
4 | Gawo 2: magawo awiri 3: magawo atatu4 : magawo anayi |
208 | Njira yaulendo ndi ma code amkati |
Mu=100 | Zovoteledwa pano (A) |
B | 4 Phase breaker N gawo ili ndi mitundu ina ya 4 yolembedwa ngati A, B, C, DA: N gawo silingakhazikitse tripper yamakono, ndi N yolumikizidwa nthawi zonse, osagwiritsidwa ntchito ndi magawo ena a 3. B: N gawo osayika tripper yamakono, ndi N gawo losagwiritsidwa ntchito ndi magawo atatu ena.C: Gawo la N lidayika katatu, ndipo gawo la N limagwira ntchito ndi magawo atatu.D: N gawo loyikapo wapaulendo wapano, ndi gawo la N lolumikizidwa nthawi zonse, Osagwiritsidwa ntchito ndi magawo ena atatu. |
Q | Wiring njira:Kutsogolo kwa mawaya a mbale: QKumbuyo kwa mawaya a mbale: HMawaya amtundu wa pulagi: R |
Zindikirani: 1. Njira yopangira ma waya: kumbuyo kwa waya wa mbale (400, 630's 4P popanda izo);plug-in mtundu wama waya (4P popanda iwo)
2. Zida zamkati zimayikidwa kumanzere kwa wosweka.
Tebulo losankhira zaukadaulo za GPM11Z MCCB
Mtundu | Adavotera voteji ya Ue (V) | Adavotera insulating voteji Ui (V) | Zovoteledwa kupirira voteji Uimp (V) | Chishango chimango Inm (A) panopa | Zovoteledwa panopa Ine (A) | Gawo nambala | Short-circuit kuswa mphamvu | Idavoteredwa kwakanthawi kochepa kupirira Icw (kA) 1s | Kuchita kwa ntchito | ||
Icu (kA) yoyezedwa kwambiri | Kuvotera kuthamanga kwafupipafupi kuphwanya mphamvu Ics (kA) | Moyo wamakina (nthawi) | Moyo Wamagetsi (nthawi) | ||||||||
GPM11Z-100 | AC400 | Mtengo wa AC690 | AC8000 | 100 | 32, 100 | 3, 4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Gome losankhidwa mwaukadaulo la GPM11 MCCB
Mtundu | Adavotera voteji yogwira ntchito Ue | Adavotera voteji ya Ui | Mphamvu zoyezedwa zimapirira voltage Uimp | Frame class idavotera Inm A pano | Zovoteledwa mu (A) | Gawo nambala | Khodi yamphamvu kwambiri yothyoka pafupipafupi | Zovoteledwa zazifupi -kutha kuthyolako kuzungulira | Kuvotera kuthamanga kwafupipafupi kuphwanya mphamvu Ics (kA) | Mtundu wa chipangizo chaulendo | Kugwira ntchito (nthawi) | |
Khalani ndi moyo | No-Live | |||||||||||
Chithunzi cha GPM11-63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Kutentha kwa electromagnetic | 3000 | 7000 |
3, 4 | S | 25 | 18 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 3000 | 7000 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 1500 | 6500 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 1500 | 6500 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 1500 | 6500 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 1000 | 4000 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Kutentha kwa electromagnetic | 1000 | 4000 | |||
3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | ||||||||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic | ||||||||
GPM11-800 | 800 | 630, 700, 800 | 3, 4 | S | 50 | 35 | Kutentha kwa electromagnetic | 1000 | 4000 | |||
3, 4 | H | 65 | 50 | Kutentha kwa electromagnetic |