40.5kV SF6 Circuit Breaker GPFN Series
Chitsanzo ndi Tanthauzo
Gwiritsani Ntchito Zachilengedwe
a.Kutalika: osapitirira 1000m
b.Kutentha kozungulira: -15 ℃~+40 ℃, kutentha kwa tsiku ndi tsiku sikudutsa +35 ℃
c.Chinyezi cha chilengedwe: chinyezi chapakati pa tsiku ndi tsiku: ≤95% pamwezi pafupifupi chinyezi chachibale: ≤90%
Kuthamanga kwa nthunzi tsiku ndi tsiku: ≤2.2x10-3 MPa Kuthamanga kwa nthunzi pamwezi: ≤1.8x10-3MPa
d.Kuchuluka kwa chivomerezi: osapitilira madigiri 8
e.Malo ogwiritsira ntchito: Mpweya wozungulira sumaipitsidwa ndi fumbi, utsi, mpweya wowononga ndi/kapena woyaka, nthunzi kapena nkhungu yamchere.
Zindikirani: Ngati malo enieni ogwiritsira ntchito sakukwaniritsa zomwe zili pamwambapa, chonde funsani kampani yathu.
Technical Parameter
Ayi. | Zinthu | Chigawo | Deta | |||
1 | Adavotera mphamvu | kV | 40.5 | |||
2 | Adavoteledwa pafupipafupi | Hz | 50 | |||
3 | 1min mphamvu pafupipafupi kupirira voteji | Pakati pa mitengo, Padziko lapansi | kV | 95 | ||
Ziphuphu | 118 | |||||
Mphamvu ya mphezi kupirira voltage | Pakati pa mitengo, Padziko lapansi | 185 | ||||
Ziphuphu | 215 | |||||
4 | Zovoteledwa panopa | A | 1250 1600 2000 2500 | |||
5 | Kuvotera kwakanthawi kochepa (RMS) | kA | 25 | 31.5 | ||
6 | Chiwongola dzanja chovomerezeka | 63 | 80 | |||
7 | Idavoteredwa ndi Short-circuit breaking current (RMS) | 25 | 31.5 | |||
8 | Idavoteredwa pakupanga kagawo kakang'ono (mtengo wapamwamba) | 63 | 80 | |||
9 | Adavotera nthawi yayifupi yozungulira | s | 4 | |||
10 | Adavoteledwa kachitidwe | O-0.3s-CO-180s-CO | ||||
11 | Adavoteledwa ndi vuto lakunja kwa gawo lapansi | kA | 21.7 | 27.4 | ||
12 | Mayesero osinthira chingwe akulipiritsa | A | 50 | |||
13 | Idavotera single/back-to-back capacitor bank breaking current | 800/800 | ||||
14 | Moyo wamakina | nthawi | 10000 | |||
15 | Nthawi yopumira yaifupi yozungulira | nthawi | 30 | |||
16 | Sekondale dera 1 mphindi mphamvu pafupipafupi kupirira voteji | 2000 | ||||
17 | Ovoteledwa voteji ntchito | Kutseka koyilo | V | DC110/220, AC220 | ||
Koyilo yotsegula | V | DC110/220, AC220 | ||||
18 | Voteji yovotera yamagetsi osungira mphamvu | W | DC110/220, AC220 | |||
19 | Mphamvu yovotera yamagetsi osungira mphamvu | s | 250 | |||
20 | Nthawi yosungira mphamvu (voteji yovotera) | s | ≤10 | |||
21 | Kuthamanga kwa gasi wa SF6 (kuthamanga kwa gauge pa 20 ° C) | Mpa | 0.350+ 0.02 | |||
22 | Kuthamanga kwa alamu | Mpa | 0.29±0.01 | |||
23 | Kuthamanga kochepa kogwira ntchito (kutsekereza kuthamanga) | Mpa | 0.28±0.01 | |||
24 | Kutulutsa kwapachaka | % | ≤0.5 | |||
25 | Chinyezi cha gasi | μL/L | ≤150 | |||
26 | Kusuntha kolumikizana | mm | ≥78 | |||
27 | Contact Spacing | mm | 50 ± 1.5 | |||
28 | Nthawi yotsegulira | ms | 60-78 | |||
29 | Nthawi yotseka | ms | 65-95 | |||
30 | Kutseka ndi kutsegulira kwa magawo atatu si nthawi | ≤5 | ||||
31 | Kuthamanga kwapakati (pakati pa 10ms pambuyo pa theka) | ms | 2.2-2.8 | |||
32 | Kuthamanga kwapakati (pakati pa 10ms pambuyo pa theka la njira) | ms | ≥1.5 | |||
33 | Main conductive loop resistance | μΩ ndi | ≤32(Ngolo yamanja) | ≤20 (mtundu wokhazikika) |